Skip to content
  • Geert Uytterhoeven's avatar
    drivers: sh: Disable PM runtime for multi-platform ARM with genpd · cbc41d0a
    Geert Uytterhoeven authored
    
    
    If the default PM Domain using PM_CLK is used for PM runtime, the real
    Clock Domain cannot be registered from DT later.
    
    Hence do not enable it when running a multi-platform kernel with genpd
    support on R-Car or RZ.  The CPG/MSTP Clock Domain driver will take care
    of PM runtime management of the module clocks.
    
    Now most multi-platform ARM shmobile platforms (SH-Mobile, R-Mobile,
    R-Car, RZ) use DT-based PM Domains to take care of PM runtime management
    of the module clocks, simplify the platform logic by replacing the
    explicit SoC checks by a single check for the presence of MSTP clocks in
    DT.
    
    Backwards-compatiblity with old DTs (mainly for R-Car Gen2) is provided
    by checking for the presence of a "#power-domain-cells" property in DT.
    
    The default PM Domain is still needed for:
      - backwards-compatibility with old DTs that lack PM Domain properties,
      - the CONFIG_PM=n case,
      - legacy (non-DT) ARM/shmobile platforms without genpd support
        (r8a7778, r8a7779),
      - legacy SuperH.
    
    Signed-off-by: default avatarGeert Uytterhoeven <geert+renesas@glider.be>
    Reviewed-by: default avatarUlf Hansson <ulf.hansson@linaro.org>
    Signed-off-by: default avatarSimon Horman <horms+renesas@verge.net.au>
    cbc41d0a