Skip to content
  • Eli Cohen's avatar
    IB/mlx5: Fix post send fence logic · c9b25495
    Eli Cohen authored
    If the caller specified IB_SEND_FENCE in the send flags of the work
    request and no previous work request stated that the successive one
    should be fenced, the work request would be executed without a fence.
    This could result in RDMA read or atomic operations failure due to a MR
    being invalidated. Fix this by adding the mlx5 enumeration for fencing
    RDMA/atomic operations and fix the logic to apply this.
    
    Fixes: e126ba97
    
     ('mlx5: Add driver for Mellanox Connect-IB adapters')
    Signed-off-by: default avatarEli Cohen <eli@mellanox.com>
    Signed-off-by: default avatarLeon Romanovsky <leon@kernel.org>
    Signed-off-by: default avatarDoug Ledford <dledford@redhat.com>
    c9b25495