Skip to content
  • Stefan Richter's avatar
    firewire: sbp2: provide fallback if mgt_ORB_timeout is missing · eaf76e0d
    Stefan Richter authored
    
    
    The Unit_Characteristics entry of an SBP-2 unit directory is not
    mandatory as far as I can tell.  If it is missing, we would probably
    fail to log in into the target because firewire-sbp2 would not wait for
    status after it sent the login request.
    
    The fix moves the cleanup of tgt->mgt_orb_timeout into a place where it
    is executed exactly once before login, rather than 0..n times depending
    on the target's config ROM.  With targets with one or more
    Unit_Characteristics entries, the result is the same as before.
    
    Signed-off-by: default avatarStefan Richter <stefanr@s5r6.in-berlin.de>
    eaf76e0d