Skip to content
  • Sebastian Reichel's avatar
    HSI: ssi-protocol: Use handshake logic from n950 · 87d99063
    Sebastian Reichel authored
    
    
    When using the ssi-protocol driver with the Nokia N950, the
    following error is thrown during modem powered up sequence.
    
    [13852.274993]  port0: SSI error: 0x01
    [13852.279205] ssi-protocol ssi-protocol: RX error detected
    [13852.284820] ssi-protocol ssi-protocol: Main state: 1
    [13852.290069] ssi-protocol ssi-protocol: Recv state: 0
    [13852.295288] ssi-protocol ssi-protocol: Send state: 0
    [13852.300537] ssi-protocol ssi-protocol: CMT Offline
    [13852.305603] ssi-protocol ssi-protocol: Wake test 1
    [13852.310638] ssi-protocol ssi-protocol: Data RX id: 0
    [13852.315887] ssi-protocol ssi-protocol: Data TX id: 0
    [13856.001464] ssi-protocol ssi-protocol: Watchdog trigerred
    [13856.007293] ssi-protocol ssi-protocol: Main state: 1
    [13856.012542] ssi-protocol ssi-protocol: Recv state: 0
    [13856.017761] ssi-protocol ssi-protocol: Send state: 0
    [13856.023010] ssi-protocol ssi-protocol: CMT Offline
    [13856.028045] ssi-protocol ssi-protocol: Wake test 0
    [13856.033111] ssi-protocol ssi-protocol: Data RX id: 0
    [13856.038330] ssi-protocol ssi-protocol: Data TX id: 0
    
    This patch fixes the issue by using the handshake setup from
    the Nokia N950 kernel. The new handshake sequence also works
    with the N900, so there is no need to differentiate between
    both modems.
    
    Tested-by: default avatarAaro Koskinen <aaro.koskinen@iki.fi>
    Signed-off-by: default avatarSebastian Reichel <sre@kernel.org>
    87d99063