Commit ce77e70e authored by Mike Hibler's avatar Mike Hibler

Get working on Fort PDUs (AP7941).

parent 703fbccd
......@@ -111,6 +111,11 @@ sub power {
if ($type eq "masterSwitchrPDU") {
$oids = $CtlOIDS{"rPDU"};
}
# XXX wonky APC power controllers at the fort (AP7941) return
# either masterSwitch.5 or masterSwitch.5.1.3.4.5
elsif ($type =~ /^masterSwitch.5/) {
$oids = $CtlOIDS{"rPDU"};
}
# XXX newer APC power controllers we have (AP8941, AP7900B) need to
# use this OID else they return an error on set operations (though
# the operations do work!)
......@@ -119,7 +124,8 @@ sub power {
}
}
# "sPDUOutletCtl" is ".1.3.6.1.4.1.318.1.1.4.4.2.1.3";
# "rPDUOutletControl" is ".1.3.6.1.4.1.318.1.1.12.3.3";
# "sPDUOutletCtl" is ".1.3.6.1.4.1.318.1.1.4.4.2.1.3";
if ($op eq "on") { $op = @$oids[1]; }
elsif ($op eq "off") { $op = @$oids[2]; }
elsif ($op =~ /cyc/) { $op = @$oids[3]; }
......@@ -142,6 +148,7 @@ sub status {
my $statusp = shift;
my %status;
# status for AP7941: .1.3.6.1.4.1.318.1.1.12.3.5
my $StatOID = ".1.3.6.1.4.1.318.1.1.4.2.2";
my $Status = 0;
......