<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 3.2//EN">
<html>
<head>
<title>Power Users Manual</title>
</head>
<body>
<h1>Power Users Manual</h1>
Power is a tool that uses SNMP to manage the APC Power Controllers
that are used in the Utah Testbed. It was designed to facilitate easy
control of power to the nodes in the testbed. It can turn on, turn
off, or power cycle (reboot) any machine that is plugged into an APC
power controller.
<p>
Along with power itself, there is a configuration file power.conf,
that should be found in /usr/testbed/etc/, which lists the machine
names and the IP addresses for thier power controllers and their
outlet numbers. (power itself is currently located in
/usr/testbed/bin/, and requires <a href="snmpit.html">snmpit</a> in
/usr/testbed/bin/ also)
<p>
<h3>Syntax</h3>
Syntax is as follows: (this message can be viewed by using
"<tt>power</tt>" without any parameters)
<pre>
Syntax:
power on &lt;machine> &lt;machine> ...
power off &lt;machine> &lt;machine> ...
power cycle &lt;machine> &lt;machine> ...
</pre>
<dl>
<dt><pre>power on &lt;machine> &lt;machine> ...</pre>
<dd>This command turns on the specified machines.
<dt><pre>power off &lt;machine> &lt;machine> ...</pre>
<dd>This command turns off the specified machines.
<dt><pre>power cycle &lt;machine> &lt;machine> ...</pre>
<dd>This command power cycles (reboots) the specified machines.
</dl>
Machines are specified using thier names: "<tt>test1</tt>" through
"<tt>test10</tt>", and "<tt>alpha</tt>" and "<tt>beta</tt>" for the
switches. Like most Unix commands, the keywords and machine names are
case-sensitive.
<h3>Power.conf Configuration File</h3>
A configuration file called "<tt>power.conf</tt>" should be found in
/usr/testbed/etc/, which should have the following format:
<pre>
#
#power.conf
#
# format:
# machine&lt;tab>PowerControlIP&lt;tab>Outlet#&lt;\n>
#Machine PowerControlIP Outlet#
test1 155.99.214.100 1
test2 155.99.214.100 2
test3 155.99.214.100 3
test4 155.99.214.100 4
test5 155.99.214.100 5
test6 155.99.214.100 6
test7 155.99.214.100 7
test8 155.99.214.100 8
test9 155.99.214.99 6
test10 155.99.214.99 5
alpha 155.99.214.99 7
beta 155.99.214.99 8
#
#end of power.conf
#
</pre>
As might be guessed, lines starting with "#" are comments, and the
format is simply a machine name, an IP address for its power
controller, and the outlet that it is using, all separated by tabs
(any spaces could cause incorrect results).
<p>
<address><font size=-1>
Power was written by Mac Newbold, of the Flux Research Group,
University of Utah Computer Science Dept., in April 2000.<br>
Please contact <a href="mailto:newbold@cs.utah.edu">
newbold@cs.utah.edu</a> for further information, including licensing
for use outside of the Utah Testbed, and concerning source code customization
issues.
<p>
Power &copy; 2000, Mac Newbold, Flux Research Group, Computer Science
Department, University of Utah
</font>
</address>
</body>
</html>
\ No newline at end of file
<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 3.2//EN">
<html>
<head>
<title>SnmpIt Users Manual</title>
</head>
<body>
<h1>SnmpIt Users Manual</h1>
SnmpIt is a tool that uses SNMP to manage the Intel 510T switches that
are used in the Utah Testbed. Its abilities include VLAN configuration
(create, delete, [list, configure from a file]) and configuration of
port settings (enable/disable, auto-detect speed/duplex, speed,
duplex). SnmpIt is also used by <a href="power.html">power</a> to
manage the power controllers attached to the nodes.
<p>
In the context of the testbed, this allows creating of the virtual
"links" in the topology using VLANs, and allows configuration of
different types of connections (100Mbps/10Mbps, Full/Half duplex), and
forcing a link to go down by disabling it on the switch. Using <a
href="power.html">power</a>, you can also force an entire node to go
down by turning it off or rebooting it.
<p>
SnmpIt is currently located in /usr/testbed/bin/ on plastic and the
testbed nodes.
<ul>
<li><a href="#syntax">SnmpIt Syntax</a>
<li><a href="#general">General Commands</a>
<li><a href="#VLAN">VLAN Configuration Commands</a>
<li><a href="#port">Port Control Commands</a>
<li><a href="#power">Power Control Commands</a>
<!-- <li><a href="#"></a> -->
</ul>
<a name="syntax"></a>
<h3>Syntax</h3>
Syntax is as follows: (this message can be viewed by with
"<tt>snmpit -h</tt>")
<pre>SnmpIt! - A general purpose SNMP Tool
Syntax:
snmpit [-h] [-v] [+b|-b] [+c|-c] -i&lt;ip\>
[-p&lt;port> &lt;port> &lt;x>..&lt;y> ... ]
[-d[isable]|-e[nable]] [+a|-a] [-s&lt;speed>] [-dup&lt;duplex>]
[-m&lt;vlan name>] [[-vlan&lt;MAC Addr.>] | [-f&lt;filename>]]
[-r&lt;vlan #>] [-l]
[ [-on|-off|-cyc] [-all] | [-&lt;n>] ]
-h Display this help message
-v Verbose mode (now off)
-i IP address or switch name
+b/-b Blocking mode (now off)
+c/-c Confirm Changes (now on)
-p List of port numbers and ranges
-d Disable port(s)
-e Enable port(s)
+a/-a Enable/Disable Port Auto-Negotiation of speed/duplex
-s Port Speed (10 or 100 Mbits)
-dup Port Duplex (half or full)
-f File mode - Automatically set up set of VLANs
-l List all VLANs on switch (ell, not #1)
-m Make a VLAN
-vlan Add MAC Address to VLAN
-r Remove VLAN
-on Turn on outlets
-off Turn off outlets
-cyc Power Cycle outlets
-all All outlets
-(n) Outlet #(n) (n=1-8)</pre>
<a name="general"></a>
<h3>General SnmpIt Commands</h3>
<pre>snmpit [-h] [-v] [+b|-b] [+c|-c]</pre>
<dl>
<dt><pre> -h Display this help message</pre>
<dd>When in doubt, use this for a full explanation of syntax.
<dt><pre> -v Verbose mode (now off)</pre>
<dd>Turns on extra output. Generally, SnmpIt won't say anything if it
did what you asked, but with this option, you can ask it for more
information. It will always give the appropriate error message when
something goes wrong, without regard to the verbose option.
<dt><pre> +b/-b Blocking mode (now off)</pre>
<dd>SnmpIt can operate in a blocking or a non-blocking mode. If you
have a lot of similar changes to make, non blocking mode will make it
go faster. SnmpIt defaults to non-blocking mode.
<dt><pre> +c/-c Confirm Changes (now on)</pre>
<dd>When in non-blocking mode, this can ask SnmpIt to make sure that
the changes requested were successfully carried out. This will take a
little longer, but if there were more than 10 or 15 identical changes,
the change has usually happened by the time it is checked.
</dl>
<a name="VLAN"></a>
<h3>VLAN Control Commands</h3>
<pre>snmpit -i&lt;ip>
[-m&lt;vlan name>] [[-vlan&lt;MAC Addr.>] | [-f&lt;filename>]]
[-r&lt;vlan #>] [-l]</pre>
<dl>
<dt><pre> -i IP address or switch name</pre>
<dd>IP address of switch on which to operate. Also accepts names. The
Intel 510T switches now in use in the Testbed are the following:
<pre>Alpha/155.99.214.170
Beta/155.99.214.171</pre>
<dt><pre> -m Make a VLAN</pre>
<dd>This optional command takes a VLAN name as a parameter. If no name
is given when creating a vlan, one will be chosen.
<dt><pre> -vlan Add MAC Address to VLAN</pre>
<dd>This is the command to make a VLAN. May be used in conjunction
with "<tt>-m</tt>". This command takes as its parameters a list of MAC
addresses. The list can include MAC addresses from another switch, but
an identical VLAN will have to be created on the other switch for full
VLAN functionality. MAC addresses are specified as 12 character
hexadecimal strings containing digits and the letters "a" through
"f". A possible command line for configuring a VLAN might be:
<pre>snmpit -i alpha -vlan 1C2B536AF27C 008b1ca721d0</pre>
This would put the network cards with MAC addresses "1C2B536AF27C" and
"008b1ca721d0" in a VLAN together, making a "link" in the topology, as
if it were hardwired with a cable. These two MAC addresses can now
only communicate with each other, whether by broadcast, unicast, or multicast.
<dt><pre> -f File mode - Automatically set up set of VLANs</pre>
<dd>This command takes as a parameter a file name. This file will
generally be output of the assignment algorithms used to map a virtual
topology to the physical topology of the testbed. They can also be
created by hand. The important section has the following format:
<pre>START vlan
switch &lt;SwitchName/IP>
1C2B536AF27C 008b1ca721d0
1073c38b28fd 283bc8a82f8c
...
end
switch &lt;SwitchName/IP>
&lt;MAC 1> &lt;MAC 2>
&lt;MAC 3> &lt;MAC 4>
...
end
END vlan</pre>
After starting the VLAN sectiom of the file, the keyword
"<tt>switch</tt>" is followed by a switch name or IP address. Each
line after that should contain a list of MAC addresses to be put in a
VLAN together. There should be at least two, but the actual number is
unlimited. Then the keyword "<tt>end</tt>" is used before starting
another switch, and and when finished, the VLAN section is closed.
<dt><pre> -r Remove VLAN </pre>
<dd>This command takes as its parameter a VLAN number. This number is
given as output from SnmpIt every time a VLAN is created. VLAN numbers
can also be found when listing VLANs. This command simply removes the
named VLAN from the switch, effectively "disconnecting" the virtual
link that had been established.
<dt><pre> -l List all VLANs on switch (ell, not #1)</pre>
<dd>As its name suggests, this command shows a table of all VLANs on
the switch, along with their names, numbers, and the MAC addresses
that they contain.
</dl>
<a name="port"></a>
<h3>Port Control Commands</h3>
<pre>snmpit [-p&lt;port> &lt;port> &lt;x>..&lt;y> ... ]
[-d[isable]|-e[nable]] [+a|-a] [-s&lt;speed>] [-dup&lt;duplex>]</pre>
<dl>
<dt><pre> -p List of port numbers and ranges</pre>
<dd>This sets which ports will be reconfigured. It will accept
individual port numbers (from 1 to 24) or ranges in the form "x..y"
where 1 <= x,y <= 24.
<dt><pre> -d Disable port(s)</pre>
<dd>As suggested, this will disable the given port, effectively
forcing a link to go down.
<dt><pre> -e Enable port(s)</pre>
<dd>This will enable a port that has been disabled with the
"<tt>-d</tt>" command. Note that this will not fix link that has gone
down for some other reason.
<dt><pre> +a/-a Enable/Disable Port Auto-Negotiation of speed/duplex</pre>
<dd>This tells the switch to auto detect and self configure the given
ports, or with the "<tt>-a</tt" command, turn off this
feature. Default is to use 100Mbps, Full duplex, unless it is not
supported by the link, in which case it lowers one or both to 10Mbps,
Half duplex.
<dt><pre> -s Port Speed (10 or 100 Mbits)</pre>
<dd>This command takes as its parameter a number, either 10 or 100,
then configures the port to use that speed. Use of this command
automatically turns off the auto-negotiate feature.
<dt><pre> -dup Port Duplex (half or full)</pre>
<dd>This command takes as its parameter a word, either half or full,
then configures the port to use that duplex setting. Use of this command
automatically turns off the auto-negotiate feature.
</dl>
<a name="power"></a>
<h3>Power Control Commands</h3>
<pre>snmpit [ [-on|-off|-cyc] [-all] | [-&lt;n>] ]</pre>
It is strongly recommended that <a href="power.html">power</a> be used
for controlling the power settings. It has additional features,
including lookup of IP and outlet for the given machine. Please see
the power man page <a href="power.html">here</a>.
<dl>
<dt><pre> -on Turn on outlets</pre>
<dd>This turns on outlets on the power controller at the specified IP
address.
<dt><pre> -off Turn off outlets</pre>
<dd>This turns off outlets on the power controller at the specified IP
address.
<dt><pre> -cyc Power Cycle outlets</pre>
<dd>This power cycles (reboots) outlets on the power controller at the
specified IP address.
<dt><pre> -all All outlets</pre>
<dd>This causes SnmpIt to operate on all outlets on the power
controller at the specified IP address.
<dt><pre> -(n) Outlet #(n) (n=1-8)</pre>
<dd>This causes SnmpIt to operate on the specified outlet on the power
controller at the specified IP address. Examples of use are
"<tt>-1</tt>", "<tt>-4</tt>", or "<tt>-8</tt>".
</dl>
<address><font size=-1>
SnmpIt was written by Mac Newbold, of the Flux Research Group,
University of Utah Computer Science Dept., in March-April 2000.<br>
Please contact <a href="mailto:newbold@cs.utah.edu">
newbold@cs.utah.edu</a> for further information, including licensing
for use outside of the Utah Testbed, and concerning source code customization
issues.
<p>
SnmpIt &copy; 2000, Mac Newbold, Flux Research Group, Computer Science
Department, University of Utah
</font>
</address>